  • Place the sensor inside the same sealed airspace as the product. Log temperature and relative humidity together and keep the sensor away from direct contact with the sachet.
  • Compare matched packages under the same conditions. Use a control so you can see how much the sachet changes the humidity trend.
  • Evaluate the time to reach your RH target and the ability to maintain it. A humidity reading alone cannot measure the remaining capacity of a sachet.

Introduction

A single humidity reading at receiving tells you how the package looks at that moment. It leaves open questions about the first hours after sealing and what happened during a warm warehouse shift or a cooler transport leg. A humidity logger can record those changes without opening the test pack. The results depend on where the sensor sits, whether the test package matches production, and how well the control represents the same load. This guide describes a practical comparison for small retail pouches or boxes that use a sealed inner bag. It starts once you have decided where the sachet belongs.

Key Differences at a Glance

Humidity data logger

  • Records a time series of relative humidity and temperature.
  • Helps compare drying time, rebounds and time spent above a chosen threshold.
  • Requires room for the sensor and a logging interval suited to the test.

Humidity indicator card

  • Shows whether specified humidity levels have been reached, according to the card’s design and reading instructions.
  • Fits in tighter packages and is handy for an inspection at opening.
  • For how card readings relate to sachet performance, see humidity indicator cards.

Controlled headspace measurement

  • Uses a suitable probe and an established measurement method to check internal RH at a defined point.
  • Can suit a small package that cannot accommodate a logger. Work with the test provider to control air entry at the access point and allow the probe to equilibrate.

Place the Sensor in the Product Airspace

With a sealed product pouch inside an outer carton, place the logger in the pouch if you want to assess the humidity experienced by the product. A monitor in the outer carton is useful for the carton environment. The packet placement guide shows which airspace the sachet serves when a shipment has nested packaging.

Set the logger where air can reach its sensing openings, with clearance from the sachet, product and bag wall. Keep it in the equivalent position for each test pack. Avoid positions where a cold surface can cool the sensor relative to the surrounding air. If the pack is so small that the logger fills much of the airspace, presses against the product or changes how the film seals, use a smaller sensor or a suitable headspace method. Record how you instrumented the pack so the result can be interpreted in light of any changes to its construction.

How to Choose a Test Setup

Choose the acceptance criteria first. Define what matters for the product, such as a maximum acceptable RH after a defined settling period and throughout the target storage window. Use the product’s own stability or packaging requirements to establish the limits. Select a logger with a stated accuracy over that temperature and RH range. Choose a sampling interval short enough to capture the changes you care about, and check that the battery and memory cover the test.

Compare like with like. Use matched pouches, equivalent fill, the same sealing settings and the same storage exposure. For an initial comparison, test the baseline without a sachet and the candidate with a sachet. If a baseline without a sachet would put saleable items at risk, use designated test units. If the decision is between two existing sachet sizes, use each size in its own set of packs. Replicate the comparison where feasible so an unusually damp sample or a defective seal does not determine the result.

Keep a record of external conditions. Start the loggers together and mark sealing, temperature changes and the end of exposure. Measure ambient temperature and RH near the samples when feasible. A parallel ambient trace helps you distinguish changes associated with the storage environment from differences between the tested packs.

Read the Temperature and RH Curves Together

Start by comparing time to the chosen RH threshold. Then compare how long each pack remains within its acceptance range. If RH rises when temperature falls, check whether the temperature and RH curves move together. Even with little change in water vapor content, cooling can increase RH. A persistent RH rise while temperature is stable deserves a closer look at film transmission, seals, moisture released by the product and the available capacity of the sachet.

For example, if two matched trial packs both meet the target shortly after sealing but only one stays within it for the required storage period, inspect seals and repeat the comparison before attributing the difference to sachet size. If both packs miss the target, review the initial moisture load and film construction before using the desiccant sizing guide to plan a revised trial. Electronic assemblies provide a useful example of how sealed electronics packaging combines a barrier bag, desiccant and humidity monitoring.

Recommended Products from Onefine

Need Sachets for a Finished-Pack Humidity Trial?

Tell us your pouch size, barrier material, product type, target RH and expected storage conditions. If you have an RH and temperature trace from a baseline test, include it with your inquiry.

  • Small sachet formats to trial in the actual product airspace
  • Silica gel and molecular sieve options to compare for your target range
  • Help selecting trial sizes for matched, finished packages

Get a Quote →

Share this article: